inkcazelo emfutshane:

Inombolo yomthetho: CI853K01 3BSE018103R1

uphawu: ABB

Ixesha lokuhambisa: Kwi-Stock

Intlawulo: T/T

izibuko lokuthutha: xiamen

ixabiso: $1200


Iinkcukacha zeMveliso

Iithegi zeMveliso

Inkcazo

Ukwenziwa ABB
Umzekelo CI853K01
Ukuodola ulwazi 3BSE018103R1
Ikhathalogu 800xA
Inkcazo CI853K01 Dual RS232-C Interface
Imvelaphi eSweden (SE)
Ikhowudi ye-HS 85389091
Ubungakanani 16cm*16cm*12cm
Ubunzima 0.8kg

Iinkcukacha

CI853 RS-232 iimodyuli ezilandelwayo:

I-COMLI ingasetyenziswa ekwakhiweni kwe-COM3 port kwaye ngokuzikhethela kwii-CI853 port.Ubude bentambo bungandiswa kakhulu (ukuya kwiikhilomitha ezininzi) kusetyenziswa isiguquli sefiber optic.I-RS-232C yi-interface yonxibelelwano esemgangathweni esetyenziselwa unxibelelwano lwe-serial kunye ne-COMLI.I-CI853 ixhasa uTshintsho olushushu.I-COMLI yi-protocol ye-ABB yokuhanjiswa kwedatha phakathi kwabalawuli.Yenzelwe i-asynchronous master / unxibelelwano lwekhoboka kwi-half-duplex.Iprothokholi ye-COMLI ixhasa imodem yokucofa elawulwa kwisicelo.I-CI853 ixhasa zombini imowudi ye-Master/Slave kwi-COMLI.

I-MODUS RTU yiprotocol esemgangathweni esasazeke ngokubanzi ngenxa yokusebenziseka kwayo ngokulula kunye nokuthembeka.I-Modbus RTU yi-open, serial (RS-232 okanye RS-485) protocol ethathwe kwi-Master/Slave architecture etshintshiselana ngolwazi kwi-half duplex mode.Umsebenzi we-Modbus unokuqwalaselwa zombini kwi-COM izibuko ze-AC 800M kunye ne-CI853.Imodyuli yokuNcitshiswa ayifumaneki kwi-MODBUS RTU.I-CI853 ixhasa kuphela imowudi ye-Master kwi-MODBUS RTU.

 

Iimpawu kunye neenzuzo

  • I-COMLI ingasetyenziswa ekwakhiweni kwe-COM3 port kwaye ngokuzikhethela kwii-CI853 port.I-RS-232C yi-interface yonxibelelwano esemgangathweni esetyenziselwa unxibelelwano lwe-serial kunye ne-COMLI.I-CI853 ixhasa uTshintsho olushushu.I-COMLI yi-protocol ye-ABB yokuhanjiswa kwedatha phakathi kwabalawuli.
  • I-MODBUS RTU yinkqubo evulekileyo, yothotho (RS-232 okanye RS-485) ethathwe kwi-Master/Slave architecture etshintshiselana ngolwazi kwimowudi ephindwe kabini.Umsebenzi we-Modbus unokuqwalaselwa zombini kwi-COM izibuko ze-AC 800M kunye ne-CI853.
  • I-Siemens 3964R ingasetyenziswa ekwakhiweni kwi-COM3 port kunye nokuzikhethela kwi-CI853 port.Ijelo lonxibelelwano eliqhelekileyo le-RS-232C/485 liyafuneka.
  • Unxibelelwano oluzichazayo lweSerial lunokusetyenziswa kulwakhiwo kwizibuko le-COM3 (kwi-AC 800M Controller) kwaye ngokuzithandela kumazibuko e-CI853.
  • Imodyuli yeCI853 ikwaxhasa uTshintsho olushushu.

  • Ngaphambili:
  • Okulandelayo:

  • Thumela umyalezo wakho kuthi: